ND-RHC High-Precision Air Temperature & Humidity Sensor
What is the ND-RHC? The ND-RHC is a high-precision lab-grade air temperature and relative humidity sensor with optional ISO 17025 (SCS/UKAS) or NIST calibration certificates. Delivering ±0.1 °C and ±0.5–0.8 % RH accuracy from a standard radiation shield, it is the reference choice for pharmaceutical and food industry compliance, building services equipment, paper and textile manufacturing, smart agriculture, urban heat islands, greenhouses and frost alarming connected to the yDoc ML-525 datalogger.
The ND-RHC is a high-precision lab-grade air temperature and relative humidity sensor with optional ISO 17025 (SCS/UKAS) or NIST calibration certificates. Delivering ±0.1 °C and ±0.5–0.8 % RH accuracy from a standard radiation shield, it is the reference choice for pharmaceutical and food industry compliance, building services equipment, paper and textile manufacturing, smart agriculture, urban heat islands, greenhouses and frost alarming connected to the yDoc ML-525 datalogger.
Key parameters
What the ND-RHC measures
Air temperature
–40 to +85 °C (extended –50 to +100), ±0.1 °C accuracy
Relative humidity
0–100 % RH, ±0.8 % RH (extended ±0.5 %)
Radiation shield
Optional Barani Design MeteoShield for high accuracy
Calibration
ISO 9001 standard, ISO 17025 / NIST on request
Specifications
Technical specifications
| Parameter | Property | Value |
|---|---|---|
| Temperature | Range | –40 to +85 °C (extended –50 to +100 °C) |
| Resolution | 0.01 °C | |
| Accuracy (10–30 °C) | ±0.1 °C | |
| Relative humidity | Range | 0–100 % RH |
| Resolution | 0.01 % RH | |
| Accuracy | ±0.8 % RH (extended ±0.5 %) | |
| Calibration | Default | ISO 9001 standard |
| Optional | ISO 17025 (SCS, UKAS) / NIST | |
| Mechanical | Cable | 2 m |
| Output | Protocol | SDI-12 / Modbus |
| Compatibility | yDoc ML-525 datalogger |
Applications
Where the ND-RHC is used
Pharmaceutical industry
GMP-compliant temperature and humidity monitoring of cleanrooms, storage and cold chains.
Food industry
HACCP-grade environmental monitoring of food production, storage and transport.
Building services
Reference-grade T/RH for HVAC commissioning, validation and energy benchmarking.
Paper & textile
Process-critical humidity control in paper machines, textile mills and printing plants.
Smart agriculture & frost
Lab-grade field T/RH for disease modelling and accurate frost prediction.
Integration
Powered by the yDoc ML-525 datalogger
The ND-RHC connects directly to the yDoc ML-525 datalogger. The yDoc powers the sensor, schedules measurements, stores readings locally and transmits them to the Sensor-Online platform via 4G/LTE-M, NB-IoT, LoRaWAN, satellite or Ethernet — with up to 10 years of battery life.
More in this category
Related air quality sensors
CO₂, Temperature, Humidity & Barometric Pressure Sensor
Compact NDIR CO₂ sensor combined with temperature, humidity and barometric pressure — the four key parameters of ind…
Particulate Matter PM1/PM2.5/PM10 Sensor
Optical particle counter measuring PM1, PM2.5 and PM10 simultaneously. For urban air quality monitoring, construction si…
Indoor Climate Monitor (CO₂, TVOC, Motion)
Complete indoor environment sensor measuring CO₂, total volatile organic compounds (TVOC) and occupancy in one unit. D…
FAQ
Frequently asked questions about the ND-RHC
What does the ND-RHC measure?+
When is lab-grade accuracy needed?+
How does the active shield work?+
Ready to deploy the ND-RHC?
Get a quote, technical advice, or a complete bundle with the yDoc ML-525 datalogger and Sensor-Online platform subscription.